beautypg.com

8 app. a. led-indicator behavior, 1 led-behavior during normal operation, Drive state – Tandberg Data LTO-2 HH User Manual

Page 39

background image

Tandberg LTO HH Installation and User Manual

35

8 App. A. LED-Indicator Behavior

8.1 LED-behavior During Normal Operation

Drive State

1

READY LED

(Green left)

ACTIVITY

LED
(Green)

CLEAN LED
(Amber)

FAULT LED
(Amber right)

LED-test.
The LEDs are turned ON in sequence

Power-On Self-Test
Starts in parallel with the LED-test .


ON

Flashing in about
12 sec


ON

After 12 sec:
Flashing during
cartridge load


ON

OFF


ON

OFF

LED-test.

The LEDs are turned ON one-by-one.

Power-On Self-Test starts in parallel
with the LED-test

2

.

ON

ON

ON

ON

Diagnostic Activity / POST

4

Flashing

OFF

OFF

OFF

Aborting Diagnostic Test

Flashing

ON / OFF /
Flashing

ON

3

/ OFF

Flashing

Cartridge not loaded.

OFF

OFF

ON

3

/ OFF

OFF

Cartridge loaded, no activity

ON

OFF

ON

3

/ OFF

OFF

Cartridge loaded, activity

ON

Flashing

ON

3

/ OFF

OFF

Cleaning

OFF

Flashing

ON

OFF

Cartridge loading or unloading

OFF

Flashing

ON

3

/ OFF

OFF

Unrecoverable drive failure

ON / OFF

OFF

ON

3

/ OFF

Flashing

5

Firmware download

in progress

Flashing

OFF

ON

3

/ OFF

OFF

Firmware update

in progress

Flashing

Flashing

ON

3

/ OFF

OFF

Firmware download failure

6

Flashing

Flashing

ON

3

/ OFF

Flashing

5

Over temperature

7

OFF

OFF

ON

3

/ OFF

ON

Aborting Diagnostic Test

Flashing

ON / OFF

ON

3

/ OFF

Flashing

Media Error (wrong, write protected or
harmed media)

OFF

Flashing

ON

3

/ OFF

Flashing

This manual is related to the following products: