beautypg.com

3 quick start list for stand-alone, Figure 2–2 – Texas Instruments TPA102 MSOP User Manual

Page 14

background image

Quick Start List for Stand-Alone

2-4

Quick Start

2.3

Quick Start List for Stand-Alone

Follow these steps to use the TPA102 MSOP EVM stand-alone or when
connecting it into existing circuits or equipment. Connections to the TPA102
MSOP module header pins can be made via individual sockets,
wire-wrapping, or soldering to the pins, either on the top or the bottom of the
module circuit board. Numbered callouts for selected steps are shown in
Figure 2–2 and details appear in Chapter 3.

Figure 2–2.

Quick Start Module Map

GND

Vo2

C3

IN2

GND

VDD GND

IN1
GND

U1†

R1

R2

C2

R5

S1

Shutdown

C4

Vo1

GND

C7

C1

TEXAS

INSTRUMENTS

SLOP125

TPA102 MSOP EVM

C5

R4

R3

6

2

4

4

5

6

† Due to the very small size of the MSOP IC package, the standard part number TPA102 is

replaced with the code TIAAC

-

Power supply

1) Ensure that all external power sources are set to OFF.

2) Connect an external regulated power supply set to 5 V to the module VDD

and GND pins taking care to observe marked polarity.

-

Inputs and outputs

3) Ensure that the signal source level is set to minimum.

4) Connect the audio source to the module IN1, IN2, and GND pins taking

care to observe marked polarity.

5) Connect the Shutdown pin to V

DD

through a normally open switch.

6) Connect 32-

headphones to the module V

O

1, V

O

2 pins through 33

µ

F

to 1000

µ

F output-coupling capacitors (figure 3 – 8) and return to the GND

pin, or

7) For line output, connections to the V

O

1 and V

O

2 pins must be made

through 33

µ

F to 1000

µ

F output-coupling capacitors and returned to

GND.

-

Power-up

8) Verify correct voltage and input polarity and set the external power supply

to ON.

The EVM should begin operation.

9) Adjust the signal source level as needed.