Installer settings (continued) – Thermo-Serv 9901i User Manual

Page 12

background image

INSTALLER settings (continued)

ENERGY EFFICIENT RECOVERY

When turned on, the thermostat will look up to two hours before the next event and anticipate when

to turn on to reach the desired temperature.

DEADBAND SETPOINT

Deadband is used with the AUTO CHANGEOVER feature. The deadband is the temperature

difference from the setpoint temperature during which the heating or cooling will not be turned on.

This is adjustable from 2-8°F (1.0-4°C).

SECURITY CODE

Enter a code to prevent changes to the INSTALLER settings.

CONTACT INFORMATION

This allows the servicing HVAC contractor to put their name and phone number into the thermostat

to remind you when service may be required.

23

INSTALL MENU

SELECT

ENTER SECURITY CODE

FOR INSTALLER

SETTINGS

0

0 0 0

INSTALL MENU

SELECT

ENERGY EFFICIENT

RECOVERY

DISABLE

ENABLE

INSTALL MENU

SELECT

AUTOCHANGE DEADBAND

3

˚F

INSTALLER settings (continued)

AUXILIARY HEAT

The 9920i can be set to use your 2H/2C heat pump internal auxiliary heating or to use an exter-

nal add-on source. The add-on feature will be used most often when a single stage heat pump

uses a gas or electric furnace as its second stage of heating.

RESIDUAL COOL

In order to get greater efficiency from the cooling system, the fan can be programmed to run for

0 (OFF), 30, 60, 90, or 120 seconds after the air conditioner has shut off.

BALANCE POINTS

This screen will appear only when the optional outdoor sensor 9025i is connected to the

thermostat. When this sensor is used with the 9920i, you can set the lower temperature (below

which the heat pump will not run) and upper temperature (above which the 2

nd

stage heat will not

run). This promotes efficient operation of the heating system.

AUTO CHANGEOVER

When turned on, the thermostat will switch automatically between heating and cooling to maintain

the optimal temperature in your home.

22

INSTALL MENU

SELECT

AUTO CHANGEOVER

DISABLE
ENABLE

INSTALL MENU

SELECT

AUXILIARY HEAT

STANDARD - COMP. =ON

ADD ON - COMP. =OFF

INSTALL MENU

SELECT

RESIDUAL COOL

SECONDS DELAY

60

INSTALL MENU

SELECT

BALANCE POINTS

LOW BALANCE

45

˚F

HIGH BALANCE

95

˚F

BACK

EDIT

CONTACT INFORMATION

AIR EXPERTS

1-555-555-1212