Sanitizing – Taylor 161 User Manual
Page 18

14
Model 161
Operating Procedures
Sanitizing
Step 1
Prepare one gallon (3.8 liters) of an approved 100
PPM sanitizing solution (example: Kay-5r). USE
WARM WATER AND FOLLOW THE MANUFACTUR-
ER’S SPECIFICATIONS.
Step 2
Pour the sanitizing solution into the hopper and allow
it to flow into the freezing cylinder.
Figure 15
Step 3
While the solution is flowing into the freezing cylinder,
brush-clean the mix hopper, mix level float, mix inlet
hole, and air tube. Brush--clean the mix level float and
stem (non--Softecht machines only).
Figure 16
Figure 17
Step 4
Place the power switch in the ON position.
Figure 18
Note: Non--Softecht
machines:
Press
the
push-button switch.
Figure 19