beautypg.com

TOA Electronics SLDVT-40 User Manual

Page 20

background image

20

Maintenance tasK

accoMpLisHinG person

procedure

Inspecting/Cleaning Burner, Logs
and Controls

Qualified Service Technician

Inspect valve and ensure it is properly operating. Check piping
for leaks. Vacuum the control compartment, fireplace logs and
burner area.

Check Flame Patterns and Flame
Height

Qualified Service Technician

Refer to Figure 9 (SLDVT-35) or Figure 10 (SLDVT-40) on Page
10
and verify the flame pattern and height displayed by the ap-
pliance conforms to the picture. Flames must not impinge on
the logs. Ensure flames are steady (not lifting or floating).

Inspecting/Cleaning Pilot and Burner

Qualified Service Technician

Refer to Figure 12 (SIT Millivolt) or Figure 13 (Electronic) on
Page 11
. Remove any surface build-up on pilot and burner
assembly. Wipe the pilot nozzles, igniter/flame rod and hood.
Ensure the pilot flame engulfs the flame sensor as shown.

Checking Vent System

Qualified Service Technician

Inspect the vent system at the top and at the base (within the
firebox) for signs of blockage or obstruction. Look for any signs
of dislocation or deterioration of the vent components. Note:
Excessive condensation can cause corrosion of caps, pipe &
fittings (excessive condensation can be caused by long lateral
runs, too many elbows and/or exterior portions of the system
being exposed to cold weather). Also inspect wall straps or
plumbers's tape to ensure it is secure and in place.

Appliance Checkout

Qualified Service Technician

Perform the appropriate appliance checkout procedure detailed
in this manual.

Replacing Rockwool Ember Materials

Homeowner/Qualified Service
Technician

Remove old ember materials (rockwool) and vacuum the ember
placement area. Place new embers as described and shown in
Figures 7 & 8.

periodically (After the Burning Season)

Maintenance tasK

accoMpLisHinG person

procedure

Cleaning Firebox Interior

Homeowner

Carefully remove logs, rockwool, volcanic stone and vermiculite.
Vacuum out interior of the firebox. Clean firebox walls and log
grate. Replace logs, rockwool, vermiculite and volcanic stone
as detailed in this manual.

Check Flame Patterns and Flame
Height

Homeowner

Refer to

Figure 9 (SLDVT-35) or 10 (SLDVT-40) on Page 10

and verify the flame pattern and height displayed by the ap-
pliance conforms to the picture. Flames must not impinge on
the logs.

Checking Vent System

Homeowner

Inspect the vent system at the top and at the base (within the
firebox) for signs of blockage or obstruction. Look for any signs
of dislocation of the vent components.

Cleaning Front Glass Enclosure Panel

Homeowner

Clean as necessary following the directions provided in this
manual. do not toucH or atteMpt to cLean GLass
WHiLe Hot
.

annually (Before the onset of the Burning Season)

Maintenance scHeduLe

This manual is related to the following products: