MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 5
3. GENERAL PRODUCT SPECIFICATIONS
Dimensions:
5.3 x 4.0 x 1.375 inches
Weight:
1
lb
Voltage Supply:
:
8 to 24 VDC
7
to
16
VAC,
50/60
Hz
Optional Wall Transformer
115 VAC, 50/60 Hz
Current Requirements: (See Section 4 for Power Down Modes)
MIU PowerPort 2.4:
12VDC
24VDC 125VDC
120VAC 220VAC
65mA
27mA 7.5mA
6.5mA 5.5mA
MIU PowerPort 9.6:
12VDC
24VDC 125VDC
120VAC 220VAC
115mA
57mA 11mA
10mA 9mA
MIU1 PowerPort 4.4:
12VDC
24VDC 125VDC
120VAC 220VAC
160mA
69mA 14mA
12mA 9mA
MIU PowerPort 28.8:
12VDC
24VDC 125VDC
120VAC 220VAC
205mA
125mA 16mA
15mA 11mA
Surge Protection:
Power Supply: 8kVrms
Analog Line:
5kVac (MIU2.4 & 9.6)
3.75kVac
(MIU14.4
&
28.8)
Digital
Line:
ESD
±
10kV
Operating Temperature:
-40 to +85 deg C
Operating Humidity:
0 to 90% (non-condensing.)
Storage Temperature:
-55 to 100 deg C
* Note: At temperatures below 0
° F, an additional current drain of up to 350 ma
occurs as the internal proportional heater operates.