Fill in top section at installation. Copy this form each time service is required.

Fill bottom section with service notes to keep a complete log of each freezer service and maintenance history.


End User company Name_________________________________ LOG NO_______________________________
Service Contract Name/Company__________________________________________________________________
Service Contract Phone Number/Fax_______________________________________________________________
LABS-series Model/Serial Number_________________________________________________________________
KRYOS Serial Number__________________________________________________________________________
Control Version Number_________________________________________________________________________
In-service Date_________________________________________________________________________________

Describe Conditions – Actual

Describe Conditions – Controller Reading


Liquid Level – via Dipstick______________________


Liquid Level – Per Controller _____________________

Level Sensor Type ____ FG ____ 8T ____ 4T

Liquid Level Setting ____ HIGH ____ LOW

Lid ____ Open ____ Closed

Lid ____ Open ____ Closed

Filling ____ Yes ____ No

Filling ____ Yes ____ No

Temperature _________________

Temperature ________________

LN2 Supply ______ ltr ______ psi

Supply Alarm ____ On ____ Off

Note: Ice Build-up ____ a little ____ a lot

Remote Alarm ____ On ____ Off

Note: Gasket condition ____ Seals ____ Leaks

Audible Alarm ____ On ____ Off

Display Lights ____ On ____ Off

Temp. control setpoint @ ______ degrees

Taylor-Wharton Technical Services. Phone 800-898-2657 Fax 251-408-2209

Service History Log (note date and log number on each service entry)

Date:_________________________________________________________________________________________
Date:_________________________________________________________________________________________
Date:_________________________________________________________________________________________
Date:_________________________________________________________________________________________
Date:_________________________________________________________________________________________
Date:_________________________________________________________________________________________
Date:_________________________________________________________________________________________
Date:_________________________________________________________________________________________
Date:_________________________________________________________________________________________
Date:_________________________________________________________________________________________


1 All Taylor-Wharton CryoStorage Systems must be cleaned and sterilized prior to return to Taylor-Wharton
for repair or maintenance and must be accompanied by a written statement to this effect. Any LABS-Service
CryoStorage System received without this statement will be returned to the sender, freight collect. Contact
Customer Service at 800-898-2657 for information.