Thermador CIT365 User Manual
Page 11

12
CAUTION:
Ą
Before installing, turn off at the service panel. Lock service
panel to prevent power from being turned on accidentally.
The branch-circuit breaker ampacity, the wire sizes and the connections must meet
the requirements of the National Electrical Code (or Canadian Electrical Code) and
all local codes and ordinances.
Attach flexible conduit to the junction box.
WARNING
:
Ą
To reduce the risk of electric shock and fire, do not use a
flexible power supply cord.
Connect the cooktop lead wires to the junction box supply wires in the following
order:
black (L1) to black
red (L2) to red
green wire to ground
Red wire
Black wire
Grounded green
cable
Certified UL
connector
Junction
box
House power supply
cord
Cooktop power supply
cord
If the cooktop is installed and connected as specified above, it will be completely
grounded in compliance with the National Electrical Code.
CAUTION:
Ą
Before plugging in the electrical cord, be sure all controls are in
the OFF position.
Remove everything from the cooktop surface, including stickers.
Clean cooktop surface with cooktop cleaning cream.
Turn on the power supply.
Verify that elements function properly.
ř
Electrical connection
ř
ř
Test the installation