Mode selection switch settings, Alarm/remote input settings, Abbreviation number settings – TOA Electronics ALARM INPUT UNIT C-AL80(H) User Manual
Page 7
7
1 2 3 4
1 32
33 64
65 96
97 128 129 160 161 192
193 224
225 256
Master Unit's
Switch Setting
Master
Unit 1
Slave
Unit 2
Slave
Unit 3
Slave
Unit 4
Slave
Unit 5
Slave
Unit 6
Slave
Unit 7
Slave
Unit 8
1 2 3 4
LEVEL
REMOTE OFF
ABBREVIATION No.9001
REMOTE
ALARM
ABBREVIATION No.1
REMOTE ON
EDGE
1
REMOTE
ALARM
2
ABBREVIATION No.9001
ABBREVIATION No.1
5. MODE SELECTION SWITCH SETTINGS
Perform settings of Alarm/Remote input, and alarm
intervals here.
Note
Make sure that the Power switch is set to OFF when
setting each Mode Selection switch. The Mode switch is
not correctly set if the Power switch is set to ON.
5.1. Alarm/Remote Input Settings
Using Mode Selection switch 1, select either "Alarm" or
"Remote" for Alarm/Remote input. Set the switch to the
lower "Alarm" position when selecting "Alarm," and to the
upper "Remote" position when selecting "Remote." The
"Alarm" position permits alarm indication to be displayed
and a buzzer to be sounded when there is an alarm signal
input. However, when a master/slave connection is
established, only the master unit's setting is valid.
(Factory-preset position: Alarm)
5.2. Abbreviation Number Settings
Please fix to the "Abbreviation No. 1–,"
(Factory-preset position: "Abbreviation No. 1–,")
In the event of the slave unit, its abbreviation number
increases in increment of 32. Thus, each Alarm Unit's
Alarm/Remote inputs 1 – 32 correspond to the
abbreviation numbers shown in the below table.
• Alarm/Remote input Nos. 1 – 32 vs. corresponding abbreviation Nos.
Note
The C-AL80 uses the abbreviation numbers to perform alarm activation or remote control for the Remote
Control. Therefore, the abbreviation numbers must be preprogrammed into the Remote Controller.