Advance Data Sheet: Dualeta™ iQA Series – Dual Quarter Brick

©2002-2005 TDK Innoveta Inc.
iQAFullDatasheet080505 2.doc 8/3/2006

(877) 498-0099

4/19


Absolute Maximum Ratings:

Stress in excess of Absolute Maximum Ratings may cause permanent damage to the device.

* Engineering estimate.

Input Characteristics:

Unless otherwise specified, specifications apply over all Rated Input Voltage, Resistive Load, and Temperature conditions.

Characteristic

Min

Typ

Max

Unit

Notes & Conditions

Operating Input Voltage

36

48

75

Vdc

Maximum Input Current

---

---

3.0*

A

Vin = 0 to Vin,max

Turn-on Voltage

---

34

---

Vdc

Turn-off Voltage

30*

32

---

Vdc

Hysteresis 0.5*

2

---

Vdc

Startup Delay Time from application of input voltage

---

12

---

mS

Vo = 0 to 0.1*Vo,nom;

On/Off =on,

Io=Io,max, Tc=25˚C

Startup Delay Time from on/off

---

10

---

mS

Vo = 0 to 0.1*Vo,nom; Vin = Vi,nom,
Io=Io,max,Tc=25˚C

Output Voltage Rise Time

---

50

---

mS

Io=Io,max,Tc=25˚C, Vo=0.1 to
0.9*Vo,nom

Inrush Transient

---

---

0.1

A

2

s

Input Reflected Ripple

---

15

---

mApp

See input/output ripple measurement
figure; BW = 5 MHz

Input Ripple Rejection

---

50*

---

dB

@120Hz

*Engineering Estimate

Caution: The power modules are not internally fused. An external input line normal blow fuse with a maximum value of
10A is required; see the Safety Considerations section of the data sheet.

Characteristic

Min

Max

Unit

Notes & Conditions

Continuous Input Voltage

-0.5

80

Vdc

Transient Input Voltage

---

100

Vdc

100mS max.

Isolation Voltage
Input to Output
Input to Baseplate
Output to Baseplate

---
---
---

1500
1500

500

Vdc
Vdc
Vdc


Basic insulation
Basic insulation
Operational insulation

Storage Temperature

-55

125

˚C

Operating Temperature Range (Tc)

-40

105*

˚C Maximum

baseplate

temperature.