Changeable components and test points, Chapter 3 – Texas Instruments TPS2151 User Manual
Page 15

3-1
Changeable Components and Test Points
Changeable Components and Test Points
C1, C2, C3, C4—input capacitors, at least 0.047
µ
F total on each input.
C5, C6, C8, C9—load capacitors, vary according to loads, but C5 plus C6 must
be at least 4.7
µ
F.
R2—top resistor of the resistor divider, refer to data sheet for its resistance
value.
R1—LDO_PG pullup resistor, must be at least 1k
Ω
.
A total of 16 test points are provided. Besides four black test points on the four
corners of the EVM, there are 12 more test points (11 red and 1 black) residing
on two sides of the white rectangle box at the center of the EVM. Their
respective testing signals are listed in the following table, when looking at the
EVM from top down. The test-point orders are listed from top to bottom on both
sides.
Table 3–1. Test Points and Test Signals
Left-side
Test-Point Order
Color
Signal
Right-side
Test-Point Order
Color
Signal
1
Red
SW_PG
1
Red
SW_PLDN
2
Red
SW_IN
2
Red
SW_OUT
3
Red
LDO_IN
3
Red
LDO_OUT
4
Red
SW_EN
4
Red
LDO_PLDN
5
Red
LDO_EN
5
Red
ADJ
6
Black
GND
6
Red
LDO_PG
Chapter 3