Taylor Pool Heat Pump User Manual
Page 23

C OD E
S YMPTOM
PR OB AB LE C AU SE
S OLU TION
PE
Los s of m em ory in the control
Res um ption of default param eters
Pow er failure
Pow er output variation. The c ontrol
accepts a voltage range betw een 20VAC
and 30VAC
R eset the heat pum p from
the breaker. The control is
back to factory settings ,
c all an authoriz ed
technician to recover
pers onalized settings (not
c overed by warranty)
C all an authoriz ed
technician if there are still
problem s
C O
Error of com m unication
betw een the c ontrol and the rem ote control
C ables are inc orrectly plugged in or
defective
D efective c ontrol or rem ote c ontrol
R eset the heat pum p from
the breaker.
C hec k c onnections .
C all an authoriz ed
technician
D F
For the hot-gas defrosting option. The
defrosting operation has not finis hed in the
predefined tim e.
Heat pum p stopped. Unplug the heat pum p
and then plug it back in to res tart the control.
If the problem persists, c ons ider the
following options.
R eversing valve blocked
D efrosting captor is defec tive
C om pressor is inactive in defros ting
m ode
R eset the heat pum p from
the breaker.
C all an authoriz ed
technician
FF
No water flow when pum p operated by the
control (sw im m ing pool pum p control option
only)
Res um ption of ac tivities if water flow is
detected
The valves of the heat pum p are clos ed
The pum p is disconnected
The pipes are obs truc ted
The water flow detector is defective: the
w ater circulates in the heat pum p but is
not detected
R eset the heat pum p from
the breaker.
O pen the valves of the
heat pum p
C onnec t back the heat
pum p
Unblock the pipes
C all an authoriz ed
technician
C F
Configuration of invalid option
R eset the heat pum p from
the breaker.
PF
Los s of power
Dis appear 10 sec .
Heat pum p was disconnected
There w as a power failure
R eset the heat pum p from
the breaker.
W ait
23