beautypg.com

Toshiba TELI CS3950DIF User Manual

Page 20

background image

 11 

Documents No. D4134648A

[Electronic shutter mode, Random trigger shutter mode, Exposure time: Register Value control]











* Please refer to "

Calculation of Frame Rate in Format_7

" of the Application manual for the T

EXP

.


[Electronic shutter mode, Random trigger shutter mode, Exposure time: Pulse width control]











* Please refer to "

Calculation of Frame Rate in Format_7

" of the Application manual for the T

EXP

.



* Random trigger shutter exposure delay time

In the random trigger shutter mode, there is an exposure delay time of approx. 2.6 µs from the falling
edge of the TRIG signal to the start of exposure in both the FIX mode and pulse width mode.

* Pulse width mode exposure time

In the random trigger shutter and pulse width modes, the exposure time is determined depending on
the pulse width, but the actual exposure time is pulse width + 8.6 µs.










TRIG

(Ext. IN)

CCD exposure

(Camera inside)

VIDEO DATA

(Camera output)

approx

2.6μs

TRIG disabled time

Integrate time
register value

T

EXP

Image

TRIG

(Ext. IN)

CCD exposure

(Camera inside)

VIDEO DATA

(Camera output)

approx

2.6μs

Integrate time
= pulse width + approx 8.6μs

TRIG disabled time

T

EXP

Image

TRIG

(Ext. IN)

CCD exposure

(Camera inside)

Pulse width

Integrate time

Delay time

Delay time = approx. 2.6µs
Integrate time = pulse width + approx. 8.6µs

* TRIGGER Polarity:Negative