Preset Modes
To reduce the need for adjustment for different modes, the monitor has default setting modes that
are most commonly used as given in the table below. If any of these display modes are detected, the
monitor automatically adjusts the picture size and centering. When no mode is matched, the user can
store their preferred modes in the user modes. The monitor is capable of storing up to 7 user modes.
The only condition to store as a user mode is the new display information must have 1 KHz differ-
ence for horizontal frequency or 1 Hz for vertical frequency or the sync signal polarities are differ-
ent from the default modes.
H. Freq.
Band Width
Mode
Resolution
(KHz)
(MHz)
H
V
1
VGA 640x350 70 Hz
31.47
28.322
2
VGA 720x400 70 Hz
31.47
28.322
3
VGA 640x480 60 Hz
31.47
25.175
4
MAC 640x480 66 Hz
35.00
32.24
-
-
5
VESA 640x480 72 Hz
37.86
31.5
-
-
6
VESA 640x480 75 Hz
37.50
31.5
-
-
7
VESA 800x600 56 Hz
35.16
36
+
+
8
VESA 800x600 60 Hz
37.88
40
+
+
9
VESA 800x600 75 Hz
46.88
49.5
+
+
10
VESA 800x600 72 Hz
48.08
50
+
+
11
MAC 832x624 75 Hz
49.72
57.283
-
-
12
VESA 1024x768 60 Hz
48.36
65
-
-
13
SUN 1024x768 65 Hz
52.45
70.49
-
-
14
VESA 1024x768 70 Hz
56.48
75
-
-
15
VESA 1024x768 75 Hz
60.02
78.75
+
+
16
SXGA 1280x1024 60 Hz
64
108
+
+
17
SXGA 1280x1024 75 Hz
80
135
+
+
18
SXGA 1152x864 75 Hz
67.5
108
+
+
19
SXGA 1280x960 60 Hz
60
108
+
+