beautypg.com

6 typical performance data, 6typical performance data, And 265v – Texas Instruments UCC28060EVM User Manual

Page 5: And 230 v, With and without phase management, Typical performance data

background image

6

Typical Performance Data

Efficiency

90.0%

91.0%

92.0%

93.0%

94.0%

95.0%

96.0%

97.0%

98.0%

99.0%

100.0%

10%

20%

30%

40%

50%

60%

70%

80%

90%

100%

% Output Pow er

E

ff

ic

ie

n

c

y

(%

)

Efficency at Vin 85V RMS

Efficency at Vin = 265V RMS

Efficiency at Vin = 115V RMS

91.0%

92.0%

93.0%

94.0%

95.0%

96.0%

97.0%

98.0%

10%

20%

30%

40%

50%

60%

70%

80%

90%

100%

% Output Power

E

ff

ic

ie

n

c

y

(%

)

With Phase Managem ent

Without Phase Managem ent

www.ti.com

Typical Performance Data

Figure 4

through

Figure 7

present characteristic performance data for the UCC28060EVM.

Figure 4. Efficiency at 85V

RMS

and 265V

RMS

The UCC28060 control device has phase management capability to improve light load efficiency. To
demonstrate the light load efficiency, the unit efficiency was measured with phase management enabled
and disabled at 115 V

RMS

and 230 V

RMS

input voltages. Phase management improved the light load

efficiency up to 3%. Refer to the

UCC28060 data sheet

for details on how to use the phase management

function of this device.

Figure 5. Efficiency at 115 V

RMS

, With and Without Phase Management

SLUU280B – May 2007 – Revised July 2008

UCC28060EVM 300-W Interleaved PFC Pre-Regulator

5

Submit Documentation Feedback