5 line transient – Texas Instruments UCC28060EVM User Manual
Page 10

6.5
Line Transient
Typical Performance Data
www.ti.com
A line transient test was conducted with an ac source on the reference design. The line was varied from
230 V
RMS
to 115 V
RMS
to 230 V
RMS
and the transient response was evaluated in each case. From the
oscilloscope image in
, it can be observed that the output recovered from line transients within
300ms at full load.
Figure 19. Line Transient, P
OUT
= 300W
UCC28060EVM 300-W Interleaved PFC Pre-Regulator
10
SLUU280B – May 2007 – Revised July 2008