DPM

DPM_ 1

VDPM

DPM

VBUS_

VBUS_

R

=

KVBUS_

-

ISE T

ISET

O UT

K

R

=

I

www.ti.com

Introduction

1.4

Control and Key Parameters Setting

Table 2. Control and Key Parameters Setting

Jack

Description

Factory Setting

JP1

Programs the fast-charge current setting. 500mA when JP1 ON; external setting

Jumper OFF (external setting)

when JP1 OFF

JP2

Connect /EN and /PG together when JP2 ON to enable charger when power present

Jumper OFF (external /EN)

JP3

Programs the input voltage regulation threshold. 4.5V when JP3 ON; external setting

Jumper OFF (external setting)

when JP3 OFF.

JP4

Limited power charge mode (LPCM) when JP4 ON; normal operation when JP4 OFF

Jumper OFF (normal operation)

JP5

Select external TS input or internal TS setting

Jumper ON 1-2 (external TS)

1-2 : External TS input
2-3 : Internal TS setting

JP6

The pull-up power source supplies for the LEDs

Jumper ON 2-3 (VBUS)

1-2 : BAT
2-3 : VBUS

JP7

Charger ON/OFF command

Jumper ON 1-2 (charger OFF)

1-2 : OFF
2-3 : ON

1.5

Recommendd Operating Conditions

Table 3. Recommendd Operating Conditions

Description

Min

Typ

Max

Unit

Notes

Supply voltage, V

BUS

Input voltage

4.5

7.3

V

Battery voltage, V

BAT

Voltage applied at VBAT terminal of J2

0

4.2

V

Supply current

Maximum input current

0

0.8

A

Charge current, I

chrg

Battery charge current

0

0.8

A

Operating junction temperature

0

125

°C

range, T

J

An external resistor is used to program the VBUS_DPM. The programming resistor, R

VDPM

is dictated by

the following equation:

(1)

Where:

VBUS_

DPM

is the desired input voltage regulation voltage threshold;

VBUS_

DPM_1

is the built-in offset threshold, nominally 3.5V

K

VBUS_DPM

is a gain factor found in the electrical specification.

If VDPM pin is shorted to VSS, the VBUS_

DPM

should be clamped to 3.65V.

If the VDPM pin is floated (open circuit), the IC operates in Battery Tracking Mode. In this case, VBUS
DPM threshold is internally set as V

TRK

, which is BAT+100mV (BAT>3.65V) or 3.75V (BAT

3.4V).

Connecting JP3 set 4.5V VDPM on EVM.

An external resistor is used to program the output current (50-800mA). The equation for charge current is:

(2)

Where, I

OUT

is the desired fast charge current; K

ISET

is a gain factor found in the spec.

The termination and pre-charge current are internally set at 10% and 20% of fast charge current
respectively. The pre-charge-to-fast-charge, V

lowv

threshold is set to 2.5V.

Connecting JP1 set 500mADC for fast charge current and 100mADC for pre-charge current on EVM.