beautypg.com

Installation of castors or optional legs, True food service equipment, inc, Installation / operation instructions – True Manufacturing Company Freezer / Refridgerator Swing Door T-23DT User Manual

Page 8

background image

............ www.truemfg.com ............

True Food Service Equipment, Inc.

6

6

INSTALLATION / OPERATION INSTRUCTIONS

Rail End

Lower Rail

Assembly

Snug Fit

Here

Leveling Shim

Castor

Leg

Bearing

Race

Lower Rail Assembly

Snug Fit

Here

Rail End

Thread castor into the underside of
cabinet frame rail.

Thread leg into cabinet bottom
frame rail.

The end of the leg is adjustable
to easy leveling.

Use the tool provided to tighten
the castor into place.

For leveling, insert the shim
between the castor and frame rail.

1

2

3

4

5

INSTALLATION OF CASTORS OR OPTIONAL LEGS

Important Safeguard for installation of leg/castor (Images 1-5 demonstrate procedure)

Securing Castors and Legs
To obtain maximum strength and stability of the unit,

it is important that you make sure each castor is secure.

Optional legs are hand-tightened securely against the

lower rail assembly see image 4-5. The bearing race on

the castor or the top edge of the leg must make firm

contact with the rail.
Unit leveling
Four leveling shims have been provided for leveling

castored units positioned on uneven floors. Shims must

be positioned between rail end and bearing race.
A. Turn the bearing race counter-clockwise until the

cabinet is level. Level front to back and side to side.

(diagonally)

B. Install the desired number of shims, making sure the

slot of the shim is in contact with the threaded stem

of the castor. (See image 2)

C. If more than one shim is used, turn the slot at a 90°

angle so they are not in line.

D. Turn the bearing race clockwise to tighten and secure

the castor by tightening the anchoring bolt with a

3/4 inch open-end wrench or the tool provided.

(See image 3)

CAUTION

To avoid damage to lower rail assembly, slowly raise unit to

upright position.
NOTE

Open holes located on the cross members of the frame rail

should be plugged before unit is in use.