Ethernet cable specifications – Transition Networks FD-CD-01(SM) User Manual

Page 2

background image

MDI switch setting

MDI-X switch setting

100 meters

100 meters

2 kilometers - multimode
20 kilometers - singlemode

Straight Through/Crossover Cable Requirements and Pin Specifications

The two active pairs in a CDDI
network are pins 1 & 2 and
pins 7 & 8. Use only dedicated
wire pairs (such as blue/white
& white/blue, orange/white &
white/orange) for the active
pins.

1

2

7

8

Twisted
Pair #1

Twisted
Pair #2

Straight Through Cable

1

2

7

8

Straight-through/crossover CDDI requirements are satisfied using
the MDI/MDI-X switch with straight-through cable.

CDDI cable connections between a
concentrator and the media converter require
the MDI/MDI-X switch to be set to MDI.

CDDI cable connections between the media
converter and a NIC require the switch to be
set to MDI-X

MDI

MDI-X

12V DC Input

FD-CD-01

CDDI

FDDI

FDDI to CDDI

MDI-X

position

MDI

position

Using small flatblade screwdriver
or similar tool and referring to
label at front of media converter,
set MDI/MDI-X switch position for
site installation.

CDDI Cable

1. Is the power LED on the media converter illuminated?

NO

Is the power adapter the proper type of voltage and cycle frequency for your AC outlet?
NOTE: Refer to the “Power Supply Requirements” on the back page.

Is the power adapter properly installed in the media converter and in the outlet?

Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.

YES

Proceed to step 2.

2. Is the CDDI Link LED illuminated?

NO

Check UTP cables for proper connection and pin assignment. (See above.)

Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.

YES

Proceed to step 3.

3. Is the fiber Link LED illuminated?

NO

Check fiber cables for proper connection.

Verify that TX and RX cables on media converter are connected to RX and TX ports,
respectively, on the other FDDI device.

Refer to Tech Tips available at: http://www.transition.com

Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.

YES

Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.

Troubleshooting the Media Converter

Installation Notes

The physical characteristics of the media cable must meet or exceed ANSI
X3T12 FDDI specifications.

ETHERNET CABLE SPECIFICATIONS

FDDI CABLE SPECIFICATIONS

SINGLEMODE
Fiber-optic Cable Recommended:

9 µm singlemode fiber

Fiber-optic Transmitter Power:

min: -15.0

dBm

max: -8.0

dBm

Fiber-optic Receiver Sensitivity:

min: -32.5

dBm

max: -8.0

dBm

Wavelength:

1300nM

Bit error rate:

10

-9

Maximum Cable Distance:

20 kilometers

MULTIMODE
Fiber-optic Cable Recommended:

62.5 / 125 µm multimode fiber

Optional:

100 / 140 µm multimode fiber

85 / 125 µm multimode fiber
50 / 125 µm multimode fiber

Fiber-optic Transmitter Power:

min: -19.0

dBm

max: -14.0

dBm

Fiber-optic Receiver Sensitivity:

min: -32.5

dBm

max: -14.0

dBm

Wavelength:

1300nM

Bit error rate:

10

-9

Maximum Cable Distance:

2 kilometers

CDDI CABLE SPECIFICATIONS
Category 5 wire or better is required. Either shielded twisted pair
(STP) or unshielded twisted pair (UTP) can be used. DO NOT USE
FLAT OR SILVER SATIN WIRE.

CATEGORY 5:

Gauge

24 to 22 AWG

Attenuation

20 dB/1000’ @ 10 MHz

Impedance 100

±10% @ 10 MHz

Maximum Cable Distance:

100 meters (330 feet)

KEEP TWISTED PAIR RUNS AS SHORT AS POSSIBLE.

Be certain that the CDDI MDI/MDI-X switch is set correctly for site installation.

Connect the power supply cable to the media converter BEFORE connecting to the outlet.

Install unit with PSU provided. (Output 12 VDC regulated, 350 mA).

Install no more than two (2) media converters in series.

FD-CD-01, FD-CD-01(SM)