SLUU195 − June 2004

4

TPS40090 Multi-Phase Buck Converter and TPS2834 Drivers Steps-Down from 12-V to 1.5-V at 100 A

TPS40090 Multi-Phase Buck Converter and TPS2834

Drivers Steps-Down from 12-V to 1.5-V at 100 A

Systems Power

Contents

1

Introduction

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

Features

5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3

Schematic

5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

Component Selection

7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

Test Setup

14

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6

Test Results/Performance Data

15

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

Layout Considerations

19

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

EVM Assembly Drawing and PCB Layout

20

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

9

List of Materials

24

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1

Introduction

The TPS40090EVM−002 multi-phase dc-to-dc converter utilizes the TPS40090 multi-phase
controller and TPS2834 adaptive driver to step down a 12-V input to 1.5-V at 420 kHz. The
output current can exceed 100 A. The TPS40090 provides fixed-frequency, peak current-mode
control with forced-phase current balancing. Phase currents are sensed by the voltage drop
across the DC resistance (DCR) of inductors. Other features include a single voltage operation,
true differential output voltage sense, user programmable current limit, capacitor-programmable
soft-start and a power good indicator. Device operation is specified in the TPS40090
datasheet

[1]

.

TPS40090EVM-002 can be configured into 2-, 3− or 4-phase operation. For 2-phase operation,
populate R65 and R66 to tie PWM2 and PWM4 up to internal 5-V and leave components in
related phases unpopulated. For 3-phase operation, tie PWM4 to BP5 through R66 only. For
4-phase operation, leave both R65 and R66 unpopulated.

In this user’s guide, all the tests are conducted under 4 phase operation.