Power Supply
Model
240 V AC, 60 Hz system:
circuit breaker
208 V AC, 60 Hz system:
circuit breaker
CEM304FS
40 Amp
30 Amp
CET304FS
40 Amp
30 Amp
CES304FS
40 Amp
30 Amp
CEM365FS
40 Amp
40 Amp
CET366FS
50 Amp
40 Amp
CES366FS
50 Amp
40 Amp
CES365FS
50 Amp
40 Amp
CAUTION:
Ą
Before installing, switch off the circuit breaker in the fuse box.
Lock circuit breaker to prevent power from being turned on accidently.
The branchĆcircuit breakers ampacity , the wire sizes and the connections must be
conform to the requirements of the National Electrical Code or Canadian Electrical
Code and all local codes and ordinances.
Attach flexible conduit to the junction box.
WARNING
:Ą
To reduce the risk of electric shock and fire, do not use a
flexible powerĆsupply cord.
Connect the cooktop lead wires to the junction box supply wires in proper phase:
black (L1) to black
red (L2) to red
blank copper wire to ground
CAUTION:
Ą
Before turning on power supply, make sure all controls are in
the OFF position.
Remove everything from the cooktop surface including stickers.
Clean cooktop surface with cooktop cleaning creme.
Switch on the circuit breaker.
Verify that elements function properly.