Smokers – Toastmaster TP209 User Manual
Page 38

Telephone: 1-906-863-4401
www.toastmastercorp.com
36
Smokers
Smokers
CONSTRUCTION:
•
Welded stainless steel
•
Fully insulated
•
Control panel accessible through front and top of unit
•
Heating elements accessible inside of cabinet and through top
CONTROLS:
•
Solid state controls
•
Indicator light for thermostat
•
Smoke on/off switch
•
Separate heat and humidity controls
•
Fan on/off switch to turn off convection air movement
•
Cook’n Hold feature ulitizes cook thermostat, hold thermostat
and 24 hour timer
DOOR SWING:
•
Smoker: 27-5/8”
CLEARANCE:
•
Allow four inches on each side and back of unit.
SERVICE CONNECTIONS:
•
ES-6 is shipped from factory to be hard wired on site.
Single phase uses three wire system.
Three phase uses four wire system.
•
208 or 240 Volt single or three phase is standard.
Please specify at time of order.
•
A 1/4” waterline is required. A water softening and filtration
system should be used to minimize mineral build-up.
SHIPPING WEIGHT:
•
400 Pounds, FOB Menominee, MI 49858
ES-6 Countertop Oven /Smoker
With Humidity
STANDARD FEATURES:
•
Stainless steel construction
•
Top ball valve for steam and smoke release
•
AutoMist humidity system
•
50
O
F - 425
O
F Cook and 50
O
F - 250
O
F Hold thermostats
•
Stainless steel door
•
5 chrome racks
•
6” legs
OPTIONS:
•
Additional Chrome Racks each (101-0025-C)
•
Casters (50-0058)
•
External Smoke Box
•
Cart with Panslides (101-9006-PS)
•
Cart without Panslides (101-9006-NP)
•
Stand with Panslides (101-6100-PS)
•
Stand without Panslides (101-6100-NP)
CAPACITY:
Shown with Optional Casters
DIMENSIONS:
Height
Width
Depth
Exterior
46-1/8”
27-3/8”
36”
Interior
26-3/8”
18-3/4”
28-7/8”
18”x26”
13”x18”
Sheet Pans
Sheet Pans
Spacing
Smoker
5
10
3-1/2”
208/1
208/3
240/1
240/3
Amp
Draw
13.5
10
12
8.5
ELECTRICAL: Watts: 2000
7
3
/
4
”
12”
27
3
/
8
”
42
3
/
8
”
3
7
/
8
”
4
1
/
2
”
2
1
/
2
”
46
1
/
8
”
3
3
/
4
”
36”
FRONT
SIDE
TOP
ELECTRICAL INLET
IN REAR OF UNIT
1
/
4
”
NPT
WATER INLET
IN REAR OF
UNIT