CAUTION

Unit may be damaged if operated when unit’s cold or heat soaked tem-

perature exceed the specified limit. If unit is operated when cold

or heat soaked temperature limit is exceeded, a full functional check

should be accomplished prior to continued use.

NOTE

If unit should overheat, an over-temperature sensor will shut down

208-240 VAC functions (charger and converter) until unit cools to

normal operating temperatures.

3-11. ENVIRONMENTAL

Operating any electrical equipment in the presence of moisture cre-

ates possible safety hazards and/or potential for equipment damage.

Every effort has been made, within the scope of existing technology

to prevent foreseeable safety hazards and make the Turbo Start 4100

moisture resistant to prevent damage or failure. If the Turbo Start

4100 is exposed to moisture, preventive measures and precautions

shall be taken to:

a.

prevent accumulation of moisture on AC and DC con-

nectors/receptacles

b.

minimize moisture entering FWD inlet and AFT out-

let cooling fan vent ports

The limits and operational constraints listed below shall apply for

the following environmental (weather) conditions:

Heavy or steady rain:

OPERATION NOT RECOMMENDED

Light rain, drizzle:

NO CONVERTER OR CHARGER 208-240 VAC

fog, snow or sleet:

POWER SHALL BE APPLIED.

Unit inlet and outlet vent ports shall be covered from exposure.

Unit shall be kept horizontal.