Conversion from natural gas to lpg, Method – Tricity Bendix TBG700 User Manual
Page 27
27
Conversion from Natural Gas to LPG
IMPORTANT
The replacement/conversion from natural gas to LPG should only be undertaken by
a competent person.
It is important to note that this model is designed for use with natural gas but can be converted for use with
butane or propane gas providing the correct injectors are fitted. The gas rate is adjusted to suit.
Method
1) Ensure that the gas taps are in the 'OFF' position
2) Isolate the hob from the electricity supply
3) Remove all pan supports, burner caps, rings, crowns and control knobs.
4) With the aid of a 7mm box spanner the burner injectors can then be unscrewed and
replaced by the appropriate LPG injectors.
TO ADJUST THE GAS RATE
With the aid of a thin bladed screwdriver completely tighten down the by pass adjustment screw.
Upon completion stick the replacement rating plate on the under side of the hob.
- DSIE456 (32 pages)
- SIE524 (32 pages)
- SE505 (32 pages)
- SOV50CH (28 pages)
- SIE 505 (36 pages)
- SIE531 (32 pages)
- CSE500 (32 pages)
- SE554 (32 pages)
- SG 205WL (27 pages)
- DSIE502 (32 pages)
- SIE553 (32 pages)
- SE501 (28 pages)
- RE60GC (36 pages)
- SI 452 (40 pages)
- SIE305 (28 pages)
- L50M2 (36 pages)
- SB411 (24 pages)
- SE402 (28 pages)
- CC500/1 (36 pages)
- SI 251 (28 pages)
- SB432 (32 pages)
- SE555 (36 pages)
- SIE557 (36 pages)
- 2590S (40 pages)
- SE 210 (20 pages)
- CSE452 (36 pages)
- U30395 SG558/1 (40 pages)
- SIE 505 SSE/BZ (36 pages)
- SE454 (36 pages)
- SIE514 (32 pages)
- SI 453 (36 pages)
- SIE 530 (36 pages)
- RE60DC (36 pages)
- ESC 5061 W GB (20 pages)
- CSB4431 (36 pages)
- SIE056 (28 pages)
- CSI 3302 (28 pages)
- SE340 (32 pages)
- CSIE501 (32 pages)
- SIE 252 (28 pages)
- CLASSIC/1 (36 pages)
- SIE515 (32 pages)
- CSIE317 (28 pages)
- SPLASHBACK SB416 (24 pages)