14. BLOCK DIAGRAMS

14.1. DA-550F

H
C

CH 1 INPUT

E

H
C

CH 2 INPUT

E

Current Limiter

Short Detector

Protection Circuit

OUTPUT 1

relay

CH 1
OUTPUT

CH 2
OUTPUT

+4 dB

-10 dB

CH 1 sensitivity
selection jumper
(+4 dB/-10 dB)

CH 1
input level
control

+4 dB

-10 dB

CH 2 sensitivity
selection jumper
(+4 dB/-10 dB)

CH 2
input level
control

ON

OFF

BRIDGE 1
ON/OFF switch

+
-

BRIDGE 1
OUTPUT

Current Limiter

Short Detector

Protection Circuit

OUTPUT 2

relay

+
-

CH 1 TO ALL
switch

Current Limiter

Short Detector

Protection Circuit

OUTPUT 3

relay

CH 3
OUTPUT

CH 4
OUTPUT

+4 dB

-10 dB

CH 3 sensitivity
selection jumper
(+4 dB/-10 dB)

CH 3
input level
control

+4 dB

-10 dB

CH 4 sensitivity
selection jumper
(+4 dB/-10 dB)

CH 4
input level
control

ON

OFF

BRIDGE 2
ON/OFF switch

+
-

BRIDGE 2
OUTPUT

Current Limiter

Short Detector

Protection Circuit

OUTPUT 4

relay

+
-

H
C

CH 3 INPUT

E

H
C

CH 4 INPUT

E

14.2. DA-500FH

H
C

CH 1 INPUT

E

H
C

CH 2 INPUT

E

Current Limiter

Short Detector

Protection Circuit

OUTPUT 1

relay

CH 1
OUTPUT

CH 2
OUTPUT

+4 dB

-10 dB

CH 1 sensitivity
selection jumper
(+4 dB/-10 dB)

CH 1
input level
control

+4 dB

-10 dB

CH 2 sensitivity
selection jumper
(+4 dB/-10 dB)

CH 2
input level
control

+
-

Current Limiter

Short Detector

Protection Circuit

OUTPUT 2

relay

+
-

CH 1 TO ALL
switch

Current Limiter

Short Detector

Protection Circuit

OUTPUT 3

relay

CH 3
OUTPUT

CH 4
OUTPUT

+4 dB

-10 dB

CH 3 sensitivity
selection jumper
(+4 dB/-10 dB)

CH 3
input level
control

+4 dB

-10 dB

CH 4 sensitivity
selection jumper
(+4 dB/-10 dB)

CH 4
input level
control

+
-

Current Limiter

Short Detector

Protection Circuit

OUTPUT 4

relay

+
-

H
C

CH 3 INPUT

E

H
C

CH 4 INPUT

E