Request sense command (03h) (continued) – Quantum 10K II User Manual
Page 248
SCSI Description
Quantum Atlas 10K II Ultra160/m SCSI Hard Disk Drives
5–181
REQUEST SENSE Command (03h) (continued)
Table 5–86 Supported Additional Sense Codes and Sense Code Qualifiers (in Hex)
(continued)
Sense Key
Sense
Code
Sense
Qualifier
Meaning
02h NOT READY (continued)
04
83
Error Reading Diskware File
04
84
Diskware Not Loaded Yet – Issue Start
CMD
04
85
Code Jumped to Dead Vector
04
86
Drive Not Ready, Configuration Page
8/HDA Mismatched
04
88
Error Reading Config Page File
04
91
Drive Not Ready, Self Scan is Running
19
00
Defect List in Error
19
01
Drive Not Ready, Unknown Defect List
19
03
Defect List Error in Grown List
31
00
Drive Not Ready, Format Corrupted
31
01
FORMAT UNIT Command Failed
40
80
Diagnostics Failure, Unknown Reason
40
81
Diagnostics Failure, RAM Failure
40
82
Diagnostics Failure, Inconsistent Data
40
83
Diagnostics Failure, HDA Diagnostic
40
84
Diagnostics Failure, PCB Diagnostic
40
85
Error Detection Code (EDC) Error
40
86
DMA Overrun Error
40
99
ROM and Resident Code are Incompatible
03h MEDIA ERROR
02
00
No Seek Complete
03
01
Pre-Amp Write Unsafe
03
84
Diag: Write Fault
0C
00
Write Error
0C
02
Write Error, Auto Reallocation Failed
0C
03
Write Error, Recommend Reassignment
11
00
Unrecovered Read Error
11
04
Unrecovered Read Error, Auto
Reallocation Failed
11
0B
Unrecovered Read Error, Recommend
Reassignment
11
81
System File Has Checksum Error
11
84
Error Reading Diskware Vector Table File
(continued)