beautypg.com

2 indicator activity during tape drive operation, Indicator activity during tape drive operation -2 – Quantum Tape Drive DLT VS80 User Manual

Page 38

background image

Chapter 4: DLT VS80 Use

4-2

May 2004

001596-01 Rev A07

4.1.1 Indicator Activity During Power-On Self-Test (POST)

Every time you power on your tape drive, it conducts a power-on self-test (POST). This test ensures
that your tape drive is working properly and is ready to use. While POST is in progress, watch the front
panel LEDs.

1.

The LEDs illuminate all at once and then turn off.

2.

The Ready (green) LED blinks during initialization and remains illuminated after POST.

3.

The tape drive emits a buzzing sound as it calibrates the read/write head’s position. POST is
complete only after the buzzing sound stops.

POST takes sever seconds to complete, after which the tape drive is ready to use.

4.1.2 Indicator Activity During Tape Drive Operation

When your tape drive is in use, a variety of indicator LEDs can blink or be illuminated.

Table 4-1

describes the circumstances under which one or more indicators are illuminated or blinking
immediately after POST.

Table 4-1.

Tape Drive Status and Indicator Activity

Tape Drive Status

Indicator Activity

Power to the tape drive

The Ready LED is on

No power to the tape drive

The Ready LED is off

The tape drive detected an unrecoverable hard
error condition

The Drive Error LED is on

The tape drive detected a recoverable
read/write error

The Clean/Media LED blinks