6.3.1 QTPCI.EXE

Quatech's "QTPCI" utility supplies the information required when

modifying the serial port settings of the application. This program should
be run from real DOS, not in a Windows DOS box.

Figure 11 shows the Basic Mode display for the ESC(LP)-100 after

the "Q" key has been pressed. In this example, the ESC(LP)-100 uses I/O
base address FF80 hex and IRQ 11. The hardware revision of the
ESC(LP)-100 is also displayed. Pressing the "N" key will show similar
information for all non-Quatech PCI devices in the system, including
those devices integrated on the motherboard.

The QTPCI program is capable only of displaying the PCI

configuration. It cannot be used to make changes.

Figure 11 --- QTPCI.EXE Basic Mode display

ESC(LP)-100 User's Manual