7.7 RS-422/485 Peripheral Connection
The DSCLP-200/300 connects to peripheral equipment through two female
D-9 connectors. The serial port connector definitions are listed in Figure 26.
3
GND
9
AUXIN-
5
AUXIN+
6
AUXOUT-
1
AUXOUT+
8
RxD-
4
RxD+
7
TxD-
2
TxD+
D-9 Connector Pin
SignalDescription
Figure 26 --- DSCLP-200/300 connector definitions