7014-082D
September 1, 2008
R
CB 1200 Pellet Stove
R
R
Straight Back Against
Wall
Inches Millimeters
A
Back Wall to Appliance
2
51
B
Side Wall to Appliance
6
152
Corner Installation
Inches Millimeters
C
Walls to Appliance
2
51
Vertical Installation
Inches Millimeters
D
Back Wall to Flue Pipe
76
E
Side Wall to Top
6
152
F
Back Wall to Appliance
7.5
191
Installations with:
3 to 3 inch Top Vent Adapter and
3 to 6 inch Offset Adapter Kit
Corner Installation
Inches Millimeters
G
Walls to Appliance
2
51
B. Clearances to Combustibles (UL and ULC)
D
E
F
A
B
Fire Risk.
Comply with all minimum clearances to
combustibles as specified.
WARNING
Failure to comply may cause house fire.
NOTE:
• Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY.
• Illustrations/diagrams are not drawn to scale.
• Actual installation may vary due to individual design
preference.
C
C
G
G
Alcove Installation
Inches Millimeters
Minimum Alcove Height
44
1117
Minimum Alcove Width
40-1/2
1029
Maximum Alcove Depth
6
915
Minimum Alcove Side Wall
6
152
Top of Unit to Combustibles
12-1/2
18