beautypg.com

Field of view, Specifications, Emissivity – Omega Engineering OSXL450 User Manual

Page 3: Maintenance, Disposal of this article

background image

Field of View

The farther the thermometer is from the target the

larger the target area will be. This relationship

between distance and target size is normally

expressed as the distance to spot, or D:S ratio. At a

distance of 6 feet, the “target” spot would be 1 foot in

diameter. The thermometer will display the average

temperature across the target area.

Specifications

Temperature Range

-20° to 320°C

(-4° to 608°F)

Accuracy

±3°F (±2°C) or 2% reading

Repeatability 2%

or

3°F

Response Time

500mSec, 95%

Spectral Response

7-18 um

Emissivity 0.95

Ambient Operating Range 6° to 40°C (32° to 105°F)

Relative Humidity

10-95% R H

noncondensing

@ up to 30°C (86°F)

Storage Temp

-20 to 65°C (-4° to 150°F)

without

battery

Weight 0.33

lb.

Dimensions

6.3 X 3.54 X 1.7"

Power 9V

Battery Life

12 hrs. - laser on

Distance to Spot

6:1

Emissivity

Most organic materials and painted or oxidized

surfaces have an emissivity of 0.95. This unit is preset

at 0.95. Inaccurate readings will result from

measuring shiny or polished metal surfaces. To

compensate, cover the surface to be measured with

masking tape or flat black paint. Measure the tape or

painted surface when the area has reached the same

temperature as the material underneath.

Maintenance

To clean the lens: Blow off loose particles using clean

compressed air. Gently brush remaining debris away

with a moist cotton cloth.

Do not use solvents to clean the lens.

Do not submerge the unit under water.

DISPOSAL OF THIS ARTICLE

Dear Customer,
If you at some point intend to dispose of this
article, then please keep in mind that many
of its components consist of valuable materials,
which can be recycled.
Please do not discharge it in the garbage bin,
but check with your local council for recycling
facilities in you area.

U.S. PAT. B1 5,368,392; 5,524,984; 5,727,880; 5,823,678; 5,823,679; 6,123,453;
6,267,500 B1; 6,341,891 B1; 6,377,400 B1; 6,540,398 B2 ; 6,614,830 B1; 6,633,434 B2;
6,659,639; 6,901,089 B1, 7,052,175 / Canada 2,114,806; 2,317,734 / France 2 756 920;
2 767 921; 2,773,213; 2 773 214 / Germany G 94 22 197.9; G 94 22 203.7, 19828454/
Holland 1007752; / U.K. Registered 2,237,493; 2,320,324; 9726133.3 / EPO 0 644,408
B2; EPO 1 085 307 A1, EPO 1 065 484 B1, EPO 1 065 483 B1.
Other U.S. and International Patents Pending.