Oracle Audio Technologies FRONTDOOR OFD-614 User Manual
Page 6
Model OFD-614
5/4/2006
Patents Pending
2.3
A.
A. ACTIVATING THE OFD TO THE MAIN INTERCOM UNIT
- 6 -
MULTI-OFD MODE
ACTIVATING AN OFD WITH AN OFD
- 7 -
2.2 ACTIVATING INTO AN EXISTING INTERCOM NETWORK
Note: If the existing network contains a GAP, MiniGAP, or another FrontDoor see “Multi-FD
Mode”.
To activate a FrontDoor into an existing intercom network, the memory on each of the
Intercoms to be used, needs to be cleared.
Note: To clear the memory on an Oracle Intercom, hold down the learn button for up to 20
seconds until a tone is heard.
Note: To clear the memory on a Flush Mount Intercom, hold down both buttons of the
Intercom for up to 20 seconds until a tone is heard.
Note: Both steps 1 & 2 must occur within 20 seconds of each other
1.
Press and release the LEARN button on an Oracle Intercom (On a Flush Mount
Intercom hold down both buttons for 3 seconds, until the channel lights start flashing
quickly).
2.
Press and release the LEARN button inside the FrontDoor unit.
Note: Activate all other Intercoms to this Intercom, NOT to the FrontDoor. (See example
below and Step B on next page.)
Note: Both steps 1 & 2 must occur within 20 seconds of each other.
1. Using the phone that is connected to the OTIU, once you hear a dial tone press:
Hang up and the LEARN light will flash for up to 15 seconds. If it does not and you
hear an error tone, check the OTIU manual.
2. On the FrontDoor, press and hold down the learn button for 1 second, to put it into
learn mode.
3. The OTIU will ring the telephone and a Caller ID will display "Unit Learned".
4. Proceed to Section 3
*
*
0 7
"BEEP"
Step A
Step B
Step B
To set a FrontDoor unit to Passive Mode, switch dipswitch #1 UP (away from the
circuit board).
Note: Any Intercoms that had been taught to this unit will have to have their memory
cleared and be re-taught to the Active Unit in the network as if they were newly
installed.
Note: Both steps 1 & 2 must occur within 20 seconds of each other.
1.
To activate the Passive FrontDoor, press the LEARN button inside the
FrontDoor unit for a second (until you hear a beep) and release it.
2.
Press the LEARN button inside the primary FrontDoor unit for a second
(until you hear a beep) and release it.
3. You will hear a tone indicating a successful activation.
4. Proceed to Section 3
channel lights start flashing quickly).
2. Press and release the LEARN button on the activated Oracle Intercom or
Flush Mount Unit.
3. Proceed to Section 3
An Oracle FrontDoor (OFD) unit is an ‘Active’ unit that takes control of the Intercom
Network. If you wish to have a second (or multiple) Oracle Frontdoor unit in the
network, or if using the Frontdoor with an Oracle Gate Access Panel, or MiniGAP,
then it will have to be placed in Passive mode. The Passive FrontDoor will become an
accessory to the Primary FrontDoor or Gate Access Panel.