beautypg.com

OPTI-UPS IS3500NT User Manual

OPTI-UPS Tools

background image

47.

Line Interactive

UPS Series

On Line UPS

Series

A

VR Series

Inverter Series

Surge Series

Green Power

Series

Standby UPS

Series

Networking

Series

Features

Specifications

IS1100NT / IS1700NT / IS2500NT / IS3500NT

* IS1100NT / IS1700NT / IS2500NT / IS3500NT

* Wide DC input range
* Output short circuit protection
* DC input polarity protection
* Sine Wave output
* Designed for any kind of load
* Adjustable low battery shutdown level

* Automatic restart of load after overload shutdown
* Audible alarm
* Thermal control cooling fan
* Generator compatible(models with AC input)
* Smart Bypass function (models with AC input)
* Full function of LED display (LCD display optional)

1000VA / 700W

1700VA / 1200W 2500VA / 1800W 3500VA / 2400W

IS1100NT

IS1700NT

IS2500NT

Pure Sine Wave

5 : 1

LCD or LED Selectable

RS232 + USB Port

0~40°C / 32~104°F

-15~55°C / 5~131°F

50dBA

(in)

(mm)

(lbs)

(kg)

INPUT

Model

On-battery Output Waveform
Crest Factor

Maximum Capacity
Nominal Input Voltage

Nominal Input Frequency
Input Voltage Range
OUTPUT
Nominal Output Voltage
Output Voltage Regulation (DC Mode)
Transfer Time
Start on Battery
Auto Restart

PROTECTION

Automatic Voltage Regulation (AVR)
Data Line Surge Protection
Surge Energy Rating

BATTERY

DC Voltage

ADVANCED WARNINGS / DIAGNOSTICS

Control Panel
Audible Alarms

COMMUNICATIONS INTERFACE
Communication Port
ENVIRONMENTAL

Operation Temperature
Storage Temperature
Audible Noise (AC Mode)
PHYSICAL

Dimensions (Physical / Packing)
(L×W×H)
Weight (Net / Gross)

IS3500NT

100/110/115/120Vac (selectable) or

200/220/230/240Vac (selectable)

47Hz ~ 65Hz, 50/60Hz auto-sensing

Yes (2 Bucks, 2 Boosts)

RJ45

<=

-30% ~ +33% for selected nominal voltage.25:25

100/110/115/120Vac (selectable) or 200/220/230/240Vac (selectable)

±3% (output voltage adjustable by using the remote set-up software)

2ms

Yes
Yes

1000VA(216 Joules), 1700VA ~ 3500VA(324 Joules)

1000VA(220 Joules), 1700VA/2500VA(440 Joules), 3500VA(660 Joules)

24Vdc(20Vdc ~ 32Vdc):1000VA / 1700VA

48Vdc(40Vdc ~ 64Vdc): 1000VA / 1700VA / 2500VA / 3500VA

72Vdc(60Vdc ~ 96Vdc): 1700VA / 2500VA / 3500VA

96Vdc(80Vdc ~128Vdc): 1700VA / 2500VA / 3500VA

108Vdc(90Vdc ~ 144Vdc):1700VA / 2500VA / 3500VA

Alarm on battery:Low battery & Battery over voltage

Alarm on abnormal operation:Over load, Short-circuit, & Over heat

17.7Ч7.1Ч7.9 / 21.3Ч11.8Ч13

450Ч180Ч200 / 540Ч300Ч330

20.Ч7.1Ч7.9 / 24Ч11.8Ч13

510Ч180Ч200 / 610Ч300Ч330

35.3 / 37.5

16 / 17

41.9 / 44.1

19 / 20

50.7 / 52.9

23 / 24

68.3 / 72.8

31 / 33