beautypg.com

OPTI-UPS Clever Series CS385B User Manual

Rear panel, For stylish home and office, Cs385b

background image

3.

For stylish home and office

Line Interactive

UPS Series

On Line UPS

Series

A

VR Series

Networking

Series

Inverter Series

Surge Series

Green Power

Series

Standby UPS

Series

* CS385B / CS530B / CS730B

CS385

CS530B

CS730B

CS385B

Breaker

Breaker

CS530B / CS730B

Bypass

Battery

Backup

Bypass
Battery

Backup

CS385 / CS530B / CS730B / CS500B

CS385B / CS530B / CS730B

* Fully digitized microprocessor control
* Energy saving (UPS sleep mode )
* 50/60Hz frequency auto sensing
* Buzzer can be muted by pressing “ON/OFF” button
* Single PCB with reliable design
* Clear LED alarms
* Cold start (DC power on)

* Short circuit and overload protection
* Advanced battery management (ABM)
* Automatic diagnostics & battery check
* Surge protection of all outlets
* EMI/RFI noise filter

Rear Panel

OUTPUT
UPS Capacity
No. of Sockets

Voltage
(on battery*)
Frequency (on battery)
Transfer Time
INPUT
Voltage
(single phase)
Frequency
PROTECTION
Unit Input
Overload Protection

Short Circuit
Spike Protection
BATTERY
Type

Typical Recharge Time
(to 90% of full capacity)
Back-up Time

Protection

PHYSICAL
Net Weight kg (lbs)
Dimension WxDxH
INTERFACE
Dry Contact (option)
USB (option)
ALARM
Battery Backup

Battery Low
UPS Works at Full Load
Overload
ENVIRONMENT
Ambient Operation

Audible Noise

CS 385B

CS 730B

385VA

730VA

NEMA 5-15R

UPS x 2, Bypass x 2

15 - 18 minutes

8 - 12 minutes

1.6 (3.52)

2.6 (5.72)

95 x 95 x 158 mm

95 x 138 x 158 mm

CS 530B

530VA

Simulated sine wave at

100V / 115V / 220V / 240V < +/- 5% AVR controlled by PWM

50 or 60Hz +/- 0.3 Hz

< 10 milliseconds, including detection time

100V +/- 20%, 110V +/- 25%

220V / 230V / 240V, 170V~280 at line input

50 or 60 Hz +/- 10% (auto sensing)

Circuit breaker for overload & short circuit protection

UPS Automatic shutdown if overload exceeds 105% of

nominal at 20 seconds, 120% at 10 seconds, 130% at 3 seconds

UPS output cut off immediately

460 joules, 2ms

Sealed, maintenance-free lead acid batteries with 3-5 years

typical life time

6 hours

Automatic self- test, Over discharge protection, short circuit

protection by fuse

2.6 (5.72)

Sends battery low & power failure signals, and receives shutdown signal from computer

Detects power failure battery low, Schedules UPS ON / OFF, displays AC input / output power status

Short beeping sound every 4 seconds

(Buzzer can be muted by pressing main switch button)

Rapid beeping sound every seconds

Long continuous beeping sound every 4 second

Continuous beeping sound

3,500 meters max elevation, 0-95% humidity

(No-condensing water),0-40 deg C

<40dBA (1 meter form surface)

Model Name

Thailand,

NEMA 5-15 Only

PC with
15” LCD

* See VS1000C on page 6

This manual is related to the following products: