beautypg.com

Oregon Scientific PROFESSIONAL WEATHER CENTER WMR200A User Manual

Page 10

background image

10

EN

TO DISABLE SLEEP MODE ON COMPUTER (WINDOWS VISTA)

1. Right click on Desktop.
2. Choose “Personalize”.
3. Click on “Screen Saver” Tab in the Display Properties window.
4. Click on “Change Power Settings” located at the bottom half of window.
5. Select “High Performance” and click “Change plan settings”.
6. Click “Change advanced power settings”.
7. Click “Sleep” and click “Hibernate after”.
8. Click “Setting” and set “0” minutes.
9. Click “Apply” and then “OK”.

CONNECTION TO PC

To upload the weather data to the computer:
Plug one end of the USB cable into the USB port and the other end into the
computer.

NOTE The USB is only used for uploading weather data. It cannot be used for
charging battery power.
To clear records:

1. Press clock area

until DATA LOGGER is displayed.

2. Press and hold MEM.
3. All LED icons will light up and turn off consecutively (right to left). Delete process

is complete and successful

after blinking of last icon

.

RESET

Press RESET to return to the default settings.

TROUBLE SHOOTING

PROBLEM

SYMPTOM

REMEDY

Barometer

Strange readings

Set unit

Calendar

Strange date / month

Change language

Clock

Cannot adjust clock

Disable radio-controlled clock

Cannot auto-synch

1.

Adjust batteries

2.

Press RESET

3.

Manually activate radio

controlled clock

Temp

Shows “LL” or “HH”

Temperature is out-of-range

Remote
sensor

Cannot locate
remote sensor

1.

Check batteries

2.

Check if sensors are

within range

PRECAUTIONS

• Do not subject the unit to excessive force, shock, dust, temperature or humidity.
• Do not cover the ventilation holes with any items such s newspapers, curtains

etc.

• Do not immerse the unit in water. If you spill liquid over it, dry it immediately with

a soft, lint-free cloth.

• Do not clean the unit with abrasive or corrosive materials.
• Do not tamper with the unit ’s internal components. This invalidates the

warranty.

• Only use fresh batteries. Do not mix new and old batteries.
• Images shown in this manual may differ from the actual display.
• When disposing of this product, ensure it is collected separately for special

treatment.

• Placement of this product on certain types of wood may result in damage to its

finish for which Oregon Scientific will not be responsible. Consult the furniture
manufacturer's care instructions for information.

• The contents of this manual may not be reproduced without the permission of the

manufacturer.

• Do not dispose old batteries as unsorted municipal waste. Collection of such

waste separately for special treatment is necessary.

• Please note that some units are equipped with a battery safety strip. Remove the

strip from the battery compartment before first use.

NOTE The technical specifications for this product and the contents of the user
manual are subject to change without notice.

NOTE Features and accessories will not be available in all countries. For more
information, please contact your local retailer.

SPECIFICATIONS

BASE STATION

Dimensions (L x W x H)

149 x 198 x 47 mm (5.9 x 7.8 x 1.9 inches)

Weight

510 g (18 oz) without battery

INDOOR BAROMETER

Barometer unit

mb/hPa, inHg and mmHg

Measuring range

700 – 1050mb/hPa

Accuracy

+/- 10 mb/hPa

Resolution

1mb (0.0 inHg)

Altitude setting

Sea level

User setting for compensation

Weather display

Sunny, Clear night, Partly Cloudy, Cloudy,

Cloudy at night, Rainy and Snowy

Memory

Historical data and bar chart for last 24hrs

INDOOR TEMPERATURE

Temp. unit

°C / °F

Displayed range

0°C to 50°C (32°F to 122°F)

Operating range

-30°C to 60°C (-4°F to 140°F)

Accuracy

0°C - 40°C: +/- 1°C (+/- 2.0°F)

40°C - 50°C: +/- 2°C (+/- 4.0°F)

Comfort

20°C to 25°C (68°F to 77°F)

Memory

Current, Min and Max temp.

Dew Point w/ Min and Max

Alarm

Hi / Lo

INDOOR RELATIVE HUMIDITY

Displayed range

2% to 98%

Operating range

25% to 90%

Resolution

1%

Accuracy

25% - 40%: +/- 7%

40% - 80%: +/- 5%

80% - 90%: +/- 7%

Comfort

40% to 70%

Memory

Current, Min and Max

Alarm

Hi / Lo

RADIO-CONTROLLED / ATOMIC CLOCK

Synchronization

Auto or disabled

Clock display

HH:MM:SS

Hour format

12hr AM/PM or 24hr

Calendar

DD/MM or MM/DD

Weekday in 5 languages

(E, G, F, I, S)

Battery

4 x UM-3 (AA) 1.5V batteries

AC adapter 6V

REMOTE WIND SENSOR UNIT

Dimensions (L x W x H)

178 x 76 x 214 mm (7 x 3 x 8.4 inches)

Weight

100 g (3.53 oz) without battery

Wind speed unit

m/s, kph, mph, knots

Speed accuracy

2 m/s ~ 10 m/s (+/- 3 m/s)

10 m/s ~ 56 m/s (+/- 10%)

Direction accuracy

16 positions

Transmission of

Approx. every 14 seconds

wind speed signal
Memory

Max speed gust

Battery

2 x UM-3 (AA) 1.5V batteries

OUTDOOR TEMPERATURE / HUMIDITY UNIT

RELATIVE TEMPERATURE
Dimensions

115 x 87 x 118 mm

(L x W x H)

(4.5 x 3.4 x 4.6 inches)

Weight

130 g (4.59 oz) without battery

Temp. unit

°C / °F

Displayed range

-50°C to 70°C (-58°F to 158°F)

Operating range

-30°C to 60°C (-4°F to 140°F)

Accuracy

-20°C – 0°C: +/- 2°C (+/- 4.0°F)

0°C - 40°C: +/- 1°C (+/- 2.0°F)

40°C - 50°C: +/- 2°C (+/- 4.0°F)

50°C - 60°C: +/- 3°C (+/- 6.0°F)

Comfort

20°C to 25°C (68°F to 77°F)

Memory

Current, Min and Max temp.

Dew Point w/ Max and Min

Wind chill temp. and min

• RELATIVE HUMIDITY
Displayed range

2% to 98%