background image

Media in Contact with Electrical Contacts

Note that the pressure media entering through Port A is in direct contact with the electrical contacts in the
switch, whereas the pressure media entering through Port B is separated from the electrical contacts by the
diaphragm.

Note: The EPDM diaphragm should not be used with petroleum products. Specify Nitrile for these applications.