beautypg.com

General repair information, Caution, Warning – Oracom ULTRA MAX 695 User Manual

Page 3

background image

309067

3

General Repair Information

CAUTION

To reduce risk of pressure control malfunction:

D Use needle nose pliers to disconnect a wire. Never

pull on wire, pull on connector.

D Mate wire connectors properly. Center flat blade of

insulated male connector in female connector.

D Route wires carefully to avoid interference with

other connections of pressure control. Do not pinch
wires between cover and control box.

Phillips screwdriver
Small flat blade

screwdriver

Needle nose pliers
Plastic mallet or 20 oz

(max) hammer

12 in. adjustable wrench
Adjustable, open-end

wrench

Torque wrench

1/4 in. hex key wrench
3/16 in. hex key wrench
5/8 in. socket wrench
3/8 in. open end wrench
1/2 in. open end wrench
3/4 in. open end wrench
7/8 in. open end wrench
High quality motor oil
Bearing grease

Tool List

1.

Keep all screws, nuts, washers, gaskets, and
electrical fittings
removed during repair proce-
dures. These parts are not normally provided with
replacement assemblies.

WARNING

ELECTRIC SHOCK HAZARD
To reduce risk of serious injury, including
electric shock, do not touch moving or
electrical parts with fingers or tools while

testing repair. Shut off and unplug sprayer when
inspection is complete. Install all covers, gaskets,
screws and washers before operating sprayer.

2.

Test repair after problem is corrected.

3.

If sprayer does not operate properly, review
repair procedure to verify procedure was done
correctly. If necessary, see Troubleshooting,
page 4, for other possible solutions.

WARNING

EXPLOSION HAZARD
Motor and drive housing are very hot
during operation and could burn skin if
touched. Flammable materials spilled on

hot, bare motor could cause fire or explosion. Have
motor shield in place during operation to reduce
risk of burns, fire or explosion.

CAUTION

Do not run sprayer dry for more than 30 seconds to
avoid damaging pump packings.

4.

Install motor shield before operation of sprayer
and replace if damaged. Motor shield directs
cooling air around motor to prevent overheating. It
can also reduce risk of burns, fire or explosion; see
preceding WARNING.

Pressure Relief Procedure

WARNING

INJECTION HAZARD
System pressure must be manually
relieved to prevent system from starting
or spraying accidentally. Fluid under high

pressure can be injected through skin and cause
serious injury. To reduce risk of injury from injec-
tion, splashing fluid, or moving parts, follow Pres-
sure Relief Procedure
whenever you:
D are instructed to relieve pressure,
D stop spraying,
D check or service any system equipment,
D or install or clean spray tip.

1. Lock gun safety latch.
2. Turn ON/OFF switch to OFF.
3. Unplug power cord.
4.

Unlock gun safety latch. Hold metal part of gun
firmly to grounded metal pail. Trigger gun to relieve
pressure.

5. Lock gun safety latch.
6. Open pressure drain valve. Leave pressure drain

valve open until ready to spray again.

If suspected that spray tip or hose is completely
clogged, or that pressure has not been fully relieved
after following steps above
, VERY SLOWLY loosen tip
guard retaining nut or hose end coupling to relieve
pressure gradually, then loosen completely. Now clear
tip or hose obstruction.