background image

POWERED SMART OS35 SERIES DATASHEET

OS35 HIGHLIGHTS

Smart air purge assures maintenance free long term

accuracy

Smart continuous auto calibration

All digital system

Smart housing resists mechanical and thermal shocks

Smart emissivity shift and ambient radiation

correction

Easy plug and play installation

Lowest cost air purged, linearized sensor on the market

Optics of 3:1 & 20:1 available

Outputs of 0-5V, 0-10V, 4-20mA, & RS232

Temperature ranges from –22 - 1832 °F (-30 - 1000 °C)

LOW impedance, results in no offset errors due to

leakage current in your input device

Custom scaling and programming for

low emissivity materials and low temperatures available

OS35-3 (3:1 FOV)

3.71” x 1.37” x 0.76” (94.3 x 34.9 x 19.4 mm)

OS35-20 (20:1 FOV)

3.71” x 1.37” x 0.76”

(94.3 x 34.9 x 19.4 mm)

& 1.63” (41.3 mm) x 0.75” diameter snout

Temperature Range

Accuracy

Repeatability

OS35-3

-30-70 °C, 0-100 °C & 0-250 °C

±1 °C or 1%

± 1.5 °C or ± 1.5%

OS35-20

0-100 °C, 0-250 °C, & 0-500 °C

± 1.5 °C or ± 1.5%

0-1000 °C

± 1.5 °C or ± 2.0%

± 1 BIT

-30-70 °C = ± 0.1 °C
0-100 °C = ± 0.1 °C

0-250 °C = ± 0.25 °C

0-500 °C = ± 0.5 °C
0-1000 °C = ± 1 °C

Interchangeability

±1 °C (1.8 °F) or 0.5%

± 1.5 °C or ± 1.5%

±1 °C (1.8 °F) or 0.5%

± 1.5 °C or ± 1.5%

±1 °C (1.8 °F) or 0.5%

± 1.5 °C or ± 1.5%

±1 °C (1.8 °F) or 0.5%

± 1.5 °C or ± 1.5%

MEASUREMENT SPECIFICATIONS

OUTLINE DRAWING