OMG-ULTRA-SIO

Page 8

Line Termination

Typically, each end of the RS-485 bus must have line terminating resistors (RS-
422 terminates at the receive end only). A 120 ohm resistor is across each RS-
530/422/485 input in addition to a 1K ohm pull-up/pull-down combination that
bias the receiver inputs. Headers E1 and E4 allow the user to customize this
interface to their specific requirements. Each jumper position corresponds to a
specific portion of the interface. If multiple OMG-ULTRA-SIO adapters are
configured in a RS-485 network, only the boards on each end should have
jumpers T, P & P ON. Refer to the following table for each position’s operation:

Name

Function

L

Connects the TX+ to RX+ for RS-485 two wire operation.

T

Adds or removes the 120 ohm termination.

L

Connects the TX- to RX- for RS-485 two wire operation.

P

Adds or removes the 1K ohm pull-down resistor in the
RS-422/RS-485 receiver circuit (Receive data only).

P

Adds or removes the 1K ohm pull-up resistor in the RS-422/RS-
485 receiver circuit (Receive data only).

L
T
L
P
P

Figure 10 - Headers E1 and E4, Line Termination