beautypg.com

Signal input, module me overview, Cct-80, electrical features 7 6 – Omega Vehicle Security CCT-80 Series User Manual

Page 7

background image

INPUT

STANDARD SIGNAL

20 mV

TARE

by internal trimmer PT1, located on the "MP"

input board

OUTPUT

0 to 20 mA or 4 to 20 mA

R

L

< 600

max. 22 mA ±3%

0 to 10 Vdc

R

L

> 1000

max. 11 V ±3%

ACCURACY

0.2 % FS

RESPONSE TIME

250 mS

GALVANIC ISOLATION

Input, Output and Power Supply are all isolated
to 2 kVeff

.

50 Hz/1 m.

GENERAL SPECIFICATIONS

RIPPLE

0.5 %

BAND PASS

1.5 Hz (-3 dB)

STORAGE TEMPERATURE

-30° to +80°C

OPERATING TEMPERATURE

-10° to +60°C

TEMPERATURE COEFFICIENT

0.015 %/°C

STANDARD POWER SUPPLY

115 Vac (±10%) 50/60 Hz

POWER CONSUMPTION

1.5 VA

TEST VOLTAGE

4 kVeff. 50 Hz/1m.

B

2

1

C

A

FIG.7

Solder pads on solder side

P1

: Output zero adjustment.

P2

: Gain amplifier adjustment.

P2

P1

OFFSET ADJUST

Solder pad 1 if closed : Adjust the low range level of the output (Offset positive coarse).
Solder pad 2 if closed : Adjust the low range level of the output (Offset negative coarse).
Jumper A if closed

: Adjust the low range level of the output (Offset negative fine).

AMPLIFIER GAIN

Jumper B if closed

: Gain at maximum level

Jumper C if closed

: Gain at medium level.

Jumpers B and C opened : Gain at minimum level.

SIGNAL INPUT, module ME
OVERVIEW

This module together with the "MP" input board, performs the signal conditioning (see Fig. 2).
This module contains the trimmers and jumpers for the amplifier gain and the low level output
(offset).
The signal input connections are made at Terminals 3, 4, 5 and 6.

This signal conditioner provides connection to 4- or 6-wire strain-gages (load-cells), which
provide a nominal of 2 mV/V or 3 mV/V output with 350

impedance. See the Connections

Section.
The signal conditioner does not provides the bridge excitation voltage, therefore is necessary
to use an external auxiliary power supply. It is advised that you use the model FAR-1 power
supply, which senses the excitation voltage and compensates the errors due to lead
resistance.
The FAR-1 provides a regulated 10 Vdc output.
The CCT-80 has an internal circuit which provides the user with tare adjust and compensation.
See the tare paragraph.

CCT-80, ELECTRICAL FEATURES

7

6