5.4

Port C Interrupt Enable Register (Base + 5)

INT7 - INT0 may be enabled by writing the appropriate bits in the Port C Interrupt Enable
Register. The corresponding I/O channel must be configured as an input channel via the Data
Port C Control Register if an interrupt is to be generated. If an I/O channel is configured as
an interrupt source (INT7 - INT0), the I/O channel continues to be a standard data input
channel (DATA23 - DATA16) and may be read just as any other input signal is read.

1 = Enables INT0; 0 = Disables INT0

INT1EN

0

1 = Enables INT1; 0 = Disables INT1

INT2EN

1

1 = Enables INT2; 0 = Disables INT2

INT2EN

2

1 = Enables INT3; 0 = Disables INT3

INT3EN

3

1 = Enables INT4; 0 = Disables INT4

INT4EN

4

1 = Enables INT5; 0 = Disables INT5

INT5EN

5

1 = Enables INT6; 0 = Disables INT6

INT6EN

6

1 = Enables INT7; 0 = Disables INT7

INT7EN

7

Description

Name

Bit

Table 5-5. Port C Interrupt Control Register

IOP-241 Users Manual 27