Omega Engineering IOP-241 User Manual
Page 16
2.2.1
Enabler Installation
The following procedure is used to install the IOP-241 Enabler:
1. Copy the file IOP241EN.EXE from the customer software CD-ROM
(directory=PCMCIA\DOS\ENABLERS) onto the root directory of the system hard
drive.
2. Using an ASCII text editor, open the system's CONFIG.SYS file located in the root
directory of the boot drive.
3. Locate the line(s) in the CONFIG.SYS file where the Card and Socket Services
software is installed.
4. AFTER the line(s) installing the Card and Socket Services software, add the
following to the CONFIG.SYS file: DEVICE = drive:\path\IOP241EN.EXE(options),
where options are the IOP-241 Client Driver command line options discussed on the
following pages. (Path is only required if the Enabler executable file is placed in a
directory other than the root directory).
5. Save the CONFIG.SYS file and exit the text editor.
6. Insert the IOP-241 into one of the system's PCMCIA slots.
NOTE:
Since the IOP-241 Enabler does not support "Hot Swapping", it is necessary
to have the IOP-241 installed when booting the system.
7. Reboot the system and note the message displayed when the IOP-241 Enabler is
loaded. If the Enabler reports an "invalid command line option", correct the entry in
the CONFIG.SYS file and reboot the system again. If the Enabler reports the desired
card configuration, the installation process is complete.
IOP-241 Users Manual 16