2 components, 1 factory built chimney system, 3 residential close clearances chimney system – Osburn Stoves by SB I 2200 User Manual
Page 8: 3 general installation requirements
7
1.5.2 Components
N
OTE
:
All connector and manufactured chimney components must be
L
ISTED
C
OMPONENTS
.
Masonry Chimneys must be
Code Complying
, and have a
listed
solid fuel burning liner (of stainless
steel or clay refractory construction).
1.5.2.1
Factory Built Chimney System
The following are the generic components required for a factory built chimney system for
residential installations:
Chimney – in the USA use a 6” diameter (152 mm) listed UL 103 HT chimney system and
components
Chimney – in Canada use 6” diameter (152 mm) listed ULC S629 chimney system and components
Manufactured (Mobile) Home Chimney System
In addition to the requirements of section 1.5.2.1 the following components are required for
manufactured (mobile) home installations:
A spark arrestor must be employed with the rain cap
Double walled connectors must be used instead of single walled connectors
For manufactured (mobile) home installations in the
USA only
and where the chimney system has
employed a
solid pack chimney
, a
vented roof flashing
must also be used.
1.5.2.3
Residential Close Clearances Chimney System
In addition to the requirements of section 1.5.2.1 the following components are required for
residential close clearances installations:
Double walled connectors must be used instead of single walled connectors
1.5.3 General Installation Requirements
C
AUTION
:
DO
NOT
F
ILL
A
NY
F
RAMED
S
PACE
A
ROUND
T
HE
F
ACTORY
-B
UILT
C
HIMNEY
W
ITH
I
NSULATION
O
R
A
NY
O
THER
M
ATERIAL
.
I
NSULATION
P
LACED
I
N
T
HIS
A
REA
C
OULD
C
AUSE
A
DJACENT
C
OMBUSTIBLES
T
O
O
VERHEAT
.
D
O
N
OT
U
SE
M
AKESHIFT
C
OMPROMISES
D
URING
I
NSTALLATION
A
S
T
HEY
M
AY
B
E
S
AFETY
H
AZARDS
,
A
ND
A
F
IRE
C
OULD
R
ESULT
.
D
O
N
OT
C
ONNECT
T
HIS
U
NIT
T
O
A
C
HIMNEY
S
YSTEM
S
ERVING
A
NOTHER
A
PPLIANCE
.
D
O
N
OT
C
UT
R
AFTERS
O
R
C
EILING
J
OISTS
W
ITHOUT
F
IRST
C
ONSULTING
A
B
UILDING
O
FFICIAL
T
O
E
NSURE
S
TRUCTURAL
I
NTEGRITY
I
S
N
OT
C
OMPROMISED
.