TROUBLESHOOTING


PROBLEM POSSIBLE

CAUSE CORRECTION

LCD does not
light

• No power input


• Check power cord

connections

• Turn on power

System will not
actuate

• Foot switch not

plugged in or
improperly plugged
in

• Defective foot switch

• Broken wire or loose

connection inside
unit

• Defective solenoid

• Defective PC board

• Check foot switch

connection


• Foot switch needs to be

repaired or replaced

• Unplug power cord and

disconnect air supply.
Remove cover and check
for broken wires or loose
connections

• Replace solenoid

• Replace PC board

System will not
pressurize

• Insufficient air

pressure

• Air hoses not

plugged in

• Regulator defective

• Increase air supply

pressure

• Check connection
• Replace regulator

System will not
pull vacuum

• Vacuum setting is

too low

• Defective solenoid

• Defective vacuum

venturi

• Defective vacuum

needle valve

• Increase vacuum setting

• Replace solenoid valve

• Replace venture

• Replace needle valve

Inconsistent
dispensing

• Air bubbles in

adhesive

• Dispense time is too

low

• Dispense needle

started to clog

• Reduce vacuum setting

• Increase dispensing time

• Replace needle











8

8

MAINTENANCE

The dispenser is designed and built to be relatively maintenance free. To assure
trouble free operation, the following recommendations should be followed:

1. Make certain air supply is clean and dry
2. Avoid turning barrels upside down or laying barrel so that material may

run through air line to internal components

3. Avoid connecting the unit to excessive moisture or solvent saturation.
4. Avoid connecting air supply exceeding 100 psi (6.9 bar) for the DX-350

and 15 psi (1.03 bar) for the DX-355

5. Use only Amyl Alcohol to clean outside surface of the main housing.
6. Use only soft cloth to clean the LCD


9

SPARE PARTS AND ACCESSORIES

For DX-3xx/2xx spare parts and accessories information, please visit the DX-
3xx/2xx User Guide webpage at http://www.okinternational.com

10 LIMITED WARRANTY


OK International warrants this product to the original purchaser for a period of one
(1) year from date of purchase to be free from material and workmanship defects but
not normal wear-and-tear, abuse and faulty installation. Defective product or
subassembly and components under warranty will be repaired or replaced (at OK
International's option) free of charge. Customer with defective product under
warranty must contact the nearest OK International office or distributor to secure a
return authorization prior to shipping the product to the assigned OK International
authorized service center. For nearest OK International office or distributor contact
information, please visit www.okinternational.com. OK International reserves the
right to make engineering product changes without notice.

11 I/O Configuration and End of Cycle Switch

For DX3xx/2xx I/O Configuration and End of Cycle Switch information, please visit
the DX-3xx/2xx User Guide webpage at http://www.okinternational.com