13

SPECIFICATIONS

Mechanical Meter Models

Flow Ranges (LPM or GPM)
Above 5 centipoise

15 to 350 / 3.96 to 92.46

Below 5 centipoise

30 to 300 / 7.93 to 79.25

Accuracy of Reading

±

1%

Maximum Viscosity

*

1000 Centipoise

Maximum Operating Pressure

**

1800 kPa / 260 PSI / 18 Bar

Operating Temperature Range

-10

°

C to +80

°

C (+14

°

F to +176

°

F) - Aluminum

-10

°

C to +120

°

C (+14

°

F to +248

°

F) - Stainless Steel

*

Unless High Viscosity Rotors are fitted.

**

Meter conforms to PED 97/23/EC CAT 1.

Item

Rec.

Part or Set

No.

Qty.

Parts

(Order from this column only)

Part Description

12

6

u

MS312S

Coverplate Screws - Litre Model

12

6

u

MS313S

Coverplate Screws (S/Steel) - Litre Model

12

6

u

MS419S

Coverplate Screws - US Gallon Model

12

6

u

MS420S

Coverplate Screws (S/Steel) - US Gallon Model

13

1

u

MS83S

Bevel Gear Set

14

1

MS140

Bottom Register Coverplate

15

4

u

MS111S

Mounting Screws

16

1

u

MS141S

Register Assembly with Coverplate - Litres

16

1

u

MS141US

Register Assembly with Coverplate - US Gallons

17

4

u

MS129S

Register Body Screws

20

1

u

MS423S

Spacer Ring (Aluminum) - US Gallons Model Only

20

1

u

MS423-1S

Spacer Ring (S/Steel) - US Gallon Model Only

Note: Complete Register Assembly Part Numbers; “Litre” Register - MS84, “US Gallons” Register - MS84U.

DIMENSIONS