15.2 General Technical Data Table
* Do not exceed the maximum length of flue stated or heater may not operate properly.
15.3 Technical Data Table
Model
UHD
[X][S][R]
150
UHD
[X][S][R]
175
UHD
[X][S][R]
200
UHD
[X][S][R]
225
UHD
[X][S][R]
250
UHD
[X][S][R]
300
UHD
[X][S][R]
350
UHD
[X][S][R]
400
Full Load Amps @ 115 V
A
2
2
2
2
2
2
6
6
Minimum Air Volume
CFM
1360
1400
2050
2100
2350
2700
3120
3420
Temperature Rise @
Minimum Air Volume
°F
(°C)
83
(28)
95
(35)
73
(23)
80
(27)
80
(27)
86
(30)
86
(30)
86
(30)
Heat Exchanger Pressure
Drop @ Minimum Air Volume
in wc
0.02
0.03
0.025
0.035
0.05
0.02
0.03
0.04
Maximum Air Volume
CFM
5800
6850
7750
8300
8850
10200
13600
14200
Temperature Rise @
Maximum Air Volume
°F
(°C)
20
(7)
20
(7)
20
(7)
20
(7)
22
(6)
23
(5)
22
(6)
22
(6)
Heat Exchanger Pressure
Drop @Maximum Air Volume
in wc
0.16
0.29
0.163
0.253
0.35
0.27
0.48
0.53
Flue Size*
in
(cm)
4 - All Models
(10)
Air Intake*
in
(cm)
4
(10)
4
(10)
4
(10)
4
(10)
4
(10)
5
(13)
5
(13)
5
(13)
Model
UHD
[X][S][R]
150
UHD
[X][S][R]
175
UHD
[X][S][R]
200
UHD
[X][S][R]
225
UHD
[X][S][R]
250
UHD
[X][S][R]
300
UHD
[X][S][R]]
350
UHD
[X][S][R]
400
Total Input
(Btu/h) x (1000)
150
175
200
225
250
300
350
385
Total Output
(Btu/h) x (1000)
123
143.5
164
184.5
205
246
287
315.7
Efficiency
%
82 - All Models
Natural Gas (G20) Data - Inlet Pressure 5.0 in wc Min., 14 in wc Max.
Burner Pressure
in wc
3.2
3.4
3.7
3.7
4.0
2.7
2.7
3.3
LPG / Propane (G31) Data - Inlet Pressure 12.0 in wc Min., 14 in wc Max.
Burner Pressure
in wc
9.9
10.4
10.5
10.7
10.5
9.4
9.3
11.1