5.1 Safety Requirement
-CSA
-UL
-TUV
-FCC CLASS B
5.2 Dielectric Strength
Primary to Secondary: 1500 VAC for 1~3 seconds.
Primary to Frame Ground: 1500 VAC for 1~3 seconds.
5.3 Insulation Resistance
Primary to Secondary: 20 Meg. ohm Minimum.
Primary to Frame Ground: 20 Meg. ohm Minimum.
5.4 Ground Leakage Current
The power supply ground leakage current shall be less than 3.5mA.
5.5 Ground Continuity
The power supply grounding continuity shall be less than 100m
͈
when the test
current is at 25A.
5.6 Reliability
The power supply have a minimum predicted MTBF(MIL-STD-217E) of 100,000