beautypg.com

Reliable i300 User Manual

Page 4

background image

CAUTION

Do not leave the machine unattended while the plug is connected to
the socket.

The iron reaches very high temperatures and it keeps being very hot
even 15 minutes after it’s been switching off. Be careful not to burn
yourself.

For complete safety, before filling the boiler, please disconnect the
plug.

While using the machine, never unscrew or remove the cap while
under pressure (1). Before removing it, make sure that it does not
give off steam anymore by shutting the boiler off, and pressing the
steam iron button (7) to release all remaining steam.

The machine has a special heating element. Only qualified
technician should replace it.

The safety cap (1) must be replaced with original parts only.


TECHNICAL DATA

Adjustable iron thermostat set from 60°C to 215°C
Bimetallic safety iron thermostat with manual reset at 275°C
Full aluminium-plated heating element at 800W – 120V
Boiler power i300: 700W
Working pressure i300: 2,5 bar
Tank nominal capacity of model i300: 1.4 litres


TROUBLESHOOTING

PROBLEM

EXPLANATION

SOLUTION

Does
steam go
out from
the boiler?

It may happen that, while filling the
tank, some water overfills the cap and
flows inside the boiler wetting the
insulating material

In order to solve the problem, we suggest
using the machine as usual so that the
insulating material dries up in about one
hour through the heat of the machine. In
case you still have this problem after one
working hour, please contact the service
centre.

Does the
steam iron
leak steam
mixed with
water?

1) While filling the tank you may have
poured too much water into it.



2) The iron plate has to be hot before
the steam passage

1) The problem will go on until the excess
water is emptied. Keep the steam button
depressed until the water in the tank is at
the correct level.

2) Please check that the temperature knob
is on the right position: “cotton

°°°)”