R3111x – Ricoh R3111x Series User Manual
Page 8
R3111x
8
•
R3111xxxxC
Topt
=
25
°C
Symbol Item
Conditions
Min.
Typ.
Max.
Unit
-V
DET
Detector
Threshold
-V
DET
× 0.98
-V
DET
× 1.02
V
V
HYS
Detector Threshold
Hysteresis
-V
DET
× 0.03
-V
DET
× 0.05
-V
DET
× 0.07
V
V
DD
=-V
DET
−0.10V
0.8
2.4
0.9V ≤ -V
DET <
2.0V
V
DD
=-V
DET
+2.0V
1.0
3.0
V
DD
=-V
DET
−0.10V
0.9
2.7
2.0V ≤ -V
DET <
3.0V
V
DD
=-V
DET
+2.0V
1.1
3.3
V
DD
=-V
DET
−0.13V
1.0
3.0
3.0V ≤ -V
DET <
4.0V
V
DD
=-V
DET
+2.0V
1.2
3.6
V
DD
=-V
DET
−0.16V
1.1
3.3
4.0V ≤ -V
DET <
5.0V
V
DD
=-V
DET
+2.0V
1.3
3.9
V
DD
=-V
DET
−0.20V
1.2
3.6
I
SS
Supply
Current
5.0V ≤ -V
DET
≤
6.0V
V
DD
=-V
DET
+2.0V
1.4
4.2
μA
V
DDH
Maximum
Operating Voltage
10
V
Topt
=25°C
0.55
0.70
V
DDL
Minimum Operating
Voltage
∗1
−40°C ≤ Topt ≤ 85°C
0.65
0.80
V
V
DS
=0.05V, V
DD
=0.70V
0.01 0.05
mA
0.9V ≤ -V
DET
<
1.1V
V
DS
=0.50V
V
DD
=0.85V
0.05 0.5
1.1V ≤ -V
DET
<
1.6V
V
DS
=0.50V
V
DD
=1.00V
0.2 1.0
Nch
1.6V ≤ -V
DET
≤ 6.0V
V
DS
=0.50V
V
DD
=1.50V
1.0 2.0
0.9V ≤ -V
DET
<
4.0V
V
DS
=−2.1V
V
DD
=4.5V
1.0 2.0
I
OUT
Output Current
(Driver Output Pin)
Pch
4.0V ≤ -V
DET
≤ 6.0V
V
DS
=−2.1V
V
DD
=8.0V
1.5 3.0
mA
t
PLH
Output Delay
Time
∗2
100
μs
Δ-V
DET
/
ΔTopt
Detector Threshold
Temperature
Coefficient
−40°C ≤ Topt ≤ 85°C
±100
ppm/
°
C
∗1: Minimum operating voltage means the value of input voltage when output voltage maintains 0.1V or less.
∗2: The time interval between the rising edge of V
DD
input pulse from 0.7V to (
+V
DET
)
+2.0V and output
voltage level becoming to ((
+V
DET
)
+2.0V)/2.