beautypg.com

Operation, R3111x – Ricoh R3111x Series User Manual

Page 12

background image

R3111x


12

OPERATION

Operation of R3111xxxxA

Vref

Ra

Rb

Rc

V

DD

OUT

GND

Tr.1

Nch

Comparator

OUT pin should be pulled-up to
V

DD

or an external voltage level.

Block Diagram (R3111xxxxA)

1

3

5

A

B

t

PLH

2 4

GND

GND

V

DDL

-V

DET

+V

DET

Detector Threshold

Released Voltage

Minimum Operating Voltage

Pull-up Voltage

Detector Threshold

Hysteresis

Supply Voltage
(V

DD

)

Output Voltage
(V

OUT

)

Step 1

2

3

4

5

Comparator (

+

)

Pin Input Voltage

I

II II II

I

Comparator Output

H

L Indefinite L

H

Tr.1 OFF

ON

Indefinite

ON OFF

Output Tr.

Nch

OFF ON Indefinite ON OFF

I

×V

DD

Rb

+Rc

Ra

+Rb+Rc

II

×V

DD

Rb

Ra

+Rb

Operation Diagram

Explanation of operation

Step 1. The output voltage is equal to the pull-up voltage.
Step 2. At Point “A”, Vref

>

=

V

DD

×(Rb+Rc)/(Ra+Rb+Rc) is true, as a result, the output of comparator is reversed

from "H" to "L", therefore the output voltage becomes the GND level. The voltage level of Point A means
a detector threshold voltage (

−V

DET

).

Step 3. When the supply voltage is lower than the minimum operating voltage, the operation of the output

transistor becomes indefinite. The output voltage is equal to the pull-up voltage.

Step 4. The output Voltage is equal to the GND level.
Step 5. At Point “B”, Vref

<

=

V

DD

×Rb/(Ra+Rb) is true, as a result, the output of comparator is reversed from "L" to

"H", then the output voltage is equal to the pull-up voltage. The voltage level of Point B means a released
voltage (

+V

DET

).

∗) The difference between a released voltage and a detector threshold voltage is a detector threshold hysteresis.

Output
Delay Time